Accident Report

Indicent | Caught in
Business | Public Works
Employee | Laborer

A worker is caught in a six-foot-deep excavation while repairing a leaking water main

Worker injured in an oxygen tank explosion

A crew of four employees made a six-foot-deep excavation on the side of a road to repair a leaking water main. Water from the leaking pipe saturated the soil, which made the trench walls unstable. While they were working, one side of the unshored excavation partially collapsed and trapped one of the workers against a pipe, injuring her leg. Two other employees were exposed when they helped her out of the trench and finished the repair work. Shoring was available to protect the workers, but was not used.

Applicable standards

1926.652(a)(1): Employees in an excavation were not protected from a cave-in by an adequate protective system.

1926.651(h)(1): Employees were working in an excavation in which there was accumulated water.

1926.651(c)(2): A safe means of egress was not located in an excavation that was four feet or more in depth.

1926.651(k)(2): When the competent person found evidence of a possible cave-in, exposed employees were not removed.

Full-color PDF version

Full version

If you want to receive the Resource Newsletter, sign up for future issues here.

Reprinting, excerpting, or plagiarizing any part of this publication is fine with us. Please send us a copy of your publication or inform the Resource editor as a courtesy. If you have questions about the information in Resource, please call 503-378-3272.

For general information, technical answers, or information about Oregon OSHA services, please call 503-378-3272 or toll-free within Oregon, 800-922-2689.